Chemicals and process industry

MAXAM nitration plant: automation, safety and ATEX

Automation of MAXAM’s nitration plant in Páramo with Schneider Electric Modicon Quantum, a safety PLC, instrumentation in ATEX areas and centralised supervision with Citect SCADA.

Client
MAXAM
Year
2013
Area
Automation
Subsector
EXPLOSIVES
Specialties
Industrial automation, Instrumentation and control, Functional safety and ATEX

Scope

Process automation, safety PLC for the protection functions, integration of instrumentation and valves in ATEX areas and centralised supervision from the control room.

  • PLCsafety PLC for the protection functions
  • ATEXinstrumentation and valves in hazardous areas
  • CitectSCADA with redundant servers
  • 20+years of collaboration with MAXAM

Functional safety and the integration of instrumentation in ATEX areas were particularly important in this project. It is part of MIESA’s collaboration with this site, where we have also carried out other projects, such as the PETN production facility.

Functional safety and safety PLC

The control system is based on Schneider Electric Modicon Quantum PLCs. The installation includes a safety PLC for the protection functions, in addition to the control of the process operation. This part of the project requires coordinating the instrumentation, the safety system and the final elements, while keeping control and protection functions separate.

Instrumentation in ATEX areas

Areas with a risk of explosive atmospheres determine the selection and integration of field equipment, signal interfaces and their connections. The project integrates instrumentation and control valves with the automation cabinets, in line with the protection requirements of each hazardous area.

Supervision with Citect SCADA

Supervision is based on Citect SCADA, with redundant servers and client stations to view the process, operate equipment and manage alarms from the control room.

Two decades of collaboration with MAXAM

MIESA has worked with MAXAM for two decades. We are currently migrating several areas of this plant, including PETN production, whose final migration phase to AVEVA Plant SCADA is under way.

The project in pictures

Do you need to automate a process with functional safety and ATEX areas?

We design the control system, the safety system and the integration of instrumentation in hazardous areas, with our own team.

  • MAXAM
  • Explosives
  • Nitration
  • Schneider Electric
  • Modicon Quantum
  • Functional safety
  • Safety PLC
  • ATEX
  • Instrumentation
  • Citect SCADA
  • AVEVA Plant SCADA
  • Redundant servers